Smart Sewage Level Monitor

From Wiki-IoT
Revision as of 01:23, 25 October 2026 by Zhe xu (talk | contribs) (Municipal IoT sensor for sewage level detection with NB-IoT transmission, basic authentication, unencrypted local storage and overflow alarm function.)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)



Smart Sewage Level Monitor
Security Grade
   
     C
   
Calculator v
Smart Sewage Level Monitor
   Brand: Generic (Parent: N/A)
   Category: Environmental & municipal IoT device • Model / Gen: 1st generation Ultrasonic sewage level sensing transmitter
   Release Date: 2021-09-20 • Status: In sale
   Classification Date:  • [N/A Official Website]

Security Evaluation

1. Device Security

Criterion Value Proof Comment
Known hardware tampering Rare —
Known vulnerabilities Rare —
Prior attacks None —
Updatability Rare —
Category Score Score: 2 / 3

2. System Security

Criterion Value Proof Comment
Authentication with other systems Partial —
Communications Encrypted with up-to-date encryption —
Storage No encryption —
Category Score Score: 2 / 3

3. User Authentication

Criterion Value Proof Comment
Account management Basic —
Authentication Basic —
Brute-force protection Absent —
Event logging Partial logging —
Passwords Require change after setup —
Category Score Score: 3 / 3

Technical Specifications

Property Details
Operating System & App FreeRTOS (Companion App: Municipal water management web platform)
Hardware (CPU / GPU) CPU: Low-power industrial 32-bit MCU • GPU: None
Memory & Storage Memory: 256KB SRAM • Storage: 4MB Flash
Power, Battery & Charging Battery: Built-in rechargeable lithium battery • Power: 3.7V lithium battery + optional solar panel • Charging: Solar charging / USB-C backup charge
Display & Camera Display: LED status indicator • Camera: None
Sound & Connectivity Sound: Buzzer overflow alarm • Connectivity: NB-IoT
Physical (Dimensions & Mass) Dimensions: Typical: 125mm × 90mm × 60mm • Mass: 350 g


This smart sewage level monitor uses ultrasonic ranging to detect the liquid level of sewage wells and drainage pipelines. It regularly uploads level data to the municipal platform and triggers an alarm when the water level exceeds the threshold to prevent sewer overflow.